We are nailfold capillaroscopy,nail fold capillaroscopy,nailfold capillary microscopy factory,Offer OEM.
Nailfold capillaroscopy microscopy

What (Influencer Name) Gets Wrong About tasly microcirculation test

tasly microcirculation test

What is tasly microcirculation test Structure?

What is tasly microcirculation test Structure?

1. 8 inch monitor

2. imported chip CCD

3. fine handwheel

4. coarse handwheel

5. platform lateral movement

6. longitudinal movement of the platform

7. finger hold

8. image spot adjustment ( could totate from left and right )

tasly microcirculation test

tasly microcirculation test changes in systemic lupus erythematosus: correlations with disease activity and autoantibody profile

tasly microcirculation test changes in systemic lupus erythematosus: correlations with disease activity and autoantibody profile

In systemic lupus erythematosus (SLE) nailfold capillaroscopy (NC) studies have described many different nonspecific patterns. We decided to evaluate NC changes in 44 SLE patients, comparing them with the main clinical, demographic and laboratory parameters, thus to define the real role for NC and its abnormalities in the management of this disease. Fifteen patients (34%) complained of Raynaud’s phenomenon; nine of them (20%) showed relevant capillaroscopic changes (capillaroscopic score >1). In details: three patients (6.8%) had loss of capillaries, while 18 (41%) had a capillary length variability, 16 (36.5%) showing shorter and two (4.5%) longer capillaries; tortuous, meandering, bizarre, ramified and/or bushy capillaries were found in 26 (59%), seven (16%), two (4.5%), three (7%) cases, respectively. An irregular distribution of the capillary array was present in six cases (14%) while microhaemorrhages were found in four cases (9%). 4 patients (9%) showed enlarged capillaries and changes of blood flow. A capillaroscopic score >1 was more frequently associated with higher ECLAM (P < 0.005) and SLEDAI (P < 0.01) activity scores, with the presence of anti-cardiolipin (P < 0.04) and anti-Sm (P < 0.04) antibodies, and also with the presence (P < 0.04) and higher titer (P < 0.001) of anti-dsDNA antibodies. No statistically significant correlation was found among the different capillaroscopy findings, age, disease duration, or treatment, nor with any clinical manifestation of the disease, such as cutaneous, renal or neurological. Our findings confirm the importance of the microvascular involvement in SLE. The NC abnormalities seem to be related to the disease activity and to the presence of many different antibodies, highly involved in the expression of SLE. NC proved to be an easy-to-perform noninvasive technique, able to achieve useful data to better evaluate such a pleomorphic disease as SLE.

tasly microcirculation test

What are sensitiv imago Frequency Compensation application?

What are sensitiv imago Frequency Compensation application?

The range of opportunities of this method application is enormously extended by the universality of the approach and the maximally individualized treatment in each specific case. Frequency Compensation is the method of a choice when a full effect is not achieved by means of standard therapy. This happens first in the cases of: chronic long-term diseases of the bronchopulmonary system, cardiovascular system, a gastrointestinal tract, recurrent painful syndromes, deficiency of the immune system, trophic disorders, and various functional imbalances.
The method is very effective at treatment of acute and chronic allergy processes, intolerance of foodstuff, and acute, chronic intoxications caused by environmental substances. Thus, Morrel’s method of allergy testing has this huge advantage, that the patient is not provoked by allergen; on the contrary, allergy Frequency-TESTING has a relieving influence on the organism, as a result of inverting the information given by the allergen.
During treatment of an allergy, the physiological adaptation of an organism’s signal from the moment by another therapy moment is used. The results of the therapy are frequently amazing owing to such an approach, the exact (definition, determination) diagnosis of causal disease factors and the synergetic effect of a two-channel technique. Frequency-THERAPY is well combined with the intake of medicines and with other physiotherapeutic methods of treatment if necessary.

Usage of Frequency Compensation in “tasly microcirculation test” device.

For more detailed instructions on the usage of Frequency Compensation, see the “tasly microcirculation test” manual. The main Frequency Compensation feature in the tasly microcirculation test is that activity is adjusted automatically, and it is not necessary to strengthen physiological fluctuations separately and to invert the pathological ones – the device does it all automatically; you simply press the button “Information influence”, select the necessary section, and therapy runs. In tasly microcirculation test the given function is automated (auto tuned) to maximize the client’s convenience.
The course of treatment consists desirably of 10 sessions every other day. For 1 session, it is advisable to do no more than six Frequency Compensation influences.

tasly microcirculation test

What is tasly microcirculation test Detector?

What is tasly microcirculation test Detector?

Microcirculation is the circulation of the blood in the smallest blood vessels,present in the vasculature embedded within organ tissues. This contrasts with macrocirculation, which is the circulation of blood to and from the organs. Microcirculation is composed of terminalarterioles, capillaries capillaries and venules which drain capillary blood. The vessels on the arterial side of the microcirculation are called the arterioles, which are well innervated, are surrounded by smooth musclecells, and are 10-100 µm in diameter.

Microcirculation is usually very smooth, but by high blood lipids, blood viscosity, erythrocyte aggregation, affect cardiovascular disease and other factors, microcirculation appears white tiny blood clots, which with the blood flow in the body.

Once the blood vessels become thin, distorted and clog the blood vessels (especially the elderly), there will be a corresponding disease, ranging from dizziness, insomnia, dizziness, numb lips, palpitation, chest tightness. If there is a large area of the brain or heart blockage will cause hemiplegia, language barriers, myocardial infarction. Therefore, early detection of thrombosis should check the microcirculation by actively antithrombotic thrombolysis, and clear the microcirculation, preventive measures.

Currently, the primary means of discovery is microcirculation microcirculation microscopic examination instrument, and general such as CT, MRI, X-ray, B-and so can not be found, so the clinical microcirculation earlier than macroscopic examination has found early diagnosis role.
Meanwhile, health groups and immunocompromised people are mainly in the microcirculation, lack of microvascular perfusion, vascular blurred, slow blood flow. By detecting the microcirculation can also quickly find the body in which the current situation in a timely manner as soon as possible be microcirculation, increase resistance and immunity, improve the sub-health conditions.

The tasly microcirculation test Microscope is an advance medical photoelectric apparatus,equipped with built in special LED light source,used mainly in observation on human nail fold capillary microcirculation or term as video Nailfold capillaroscopy,Such as capillary blood flow, abnormal microcirculation of the vascular structure, cell adhesion, through its powerful 380X(or 240X)optical magnification. Undistorted, real time dynamic video streaming via Sony CCD imaging device onto the LCD monitor screen.

Simply insert the finger to the holder below the optical lens apparatus, fine-tune to fix the focal length and uncover the desired images within seconds.Blood capilliary tasly microcirculation test is a non-invasive diagnostic tools, which is gaining large credit among physicians of different specialities in for study of skin blood capilliary network.

tasly microcirculation test

  • Have any question, Please enter the form below and click the submit button.


    *
    *
    *
    * + * = ?
    Please enter the answer to the sum & Click Submit to verify your registration.