We are nailfold capillaroscopy,nail fold capillaroscopy,nailfold capillary microscopy factory,Offer OEM.
Nailfold capillaroscopy microscopy

nail microscope Here’s a Quick Way to know

What is nail microscope?

nail microscope

nail microscope

nail microscope

nail microscope

nail microscope

nail microscope

microcirculation test machine microcirculation test machine capillary microscope

What is nail microscope microcirculation machine Detector?

Microcirculation is the circulation of the blood in the smallest blood vessels,present in the vasculature embedded within organ tissues. This contrasts with macrocirculation, which is the circulation of blood to and from the organs. Microcirculation is composed of terminalarterioles, capillaries capillaries and venules which drain capillary blood. The vessels on the arterial side of the microcirculation are called the arterioles, which are well innervated, are surrounded by smooth musclecells, and are 10-100 µm in diameter.

Microcirculation is usually very smooth, but by high blood lipids, blood viscosity, erythrocyte aggregation, affect cardiovascular disease and other factors, microcirculation appears white tiny blood clots, which with the blood flow in the body.

nailfold microcirculation microscope
nail microscope
nailfold capillary microscopy

Once the blood vessels become thin, distorted and clog the blood vessels (especially the elderly), there will be a corresponding disease, ranging from dizziness, insomnia, dizziness, numb lips, palpitation, chest tightness. If there is a large area of the brain or heart blockage will cause hemiplegia, language barriers, myocardial infarction. Therefore, early detection of thrombosis should check the microcirculation by actively antithrombotic thrombolysis, and clear the microcirculation, preventive measures.

Currently, the primary means of discovery is microcirculation microcirculation microscopic examination instrument, and general such as CT, MRI, X-ray, B-and so can not be found, so the clinical microcirculation earlier than macroscopic examination has found early diagnosis role.
Meanwhile, health groups and immunocompromised people are mainly in the microcirculation, lack of microvascular perfusion, vascular blurred, slow blood flow. By detecting the microcirculation can also quickly find the body in which the current situation in a timely manner as soon as possible be microcirculation, increase resistance and immunity, improve the sub-health conditions.

The nail microscope microcirculation machine Microscope is an advance medical photoelectric apparatus,equipped with built in special LED light source,used mainly in observation on human nail fold capillary microcirculation or term as video Nailfold capillaroscopy,Such as capillary blood flow, abnormal microcirculation of the vascular structure, cell adhesion, through its powerful 380X(or 240X)optical magnification. Undistorted, real time dynamic video streaming via Sony CCD imaging device onto the LCD monitor screen.

Simply insert the finger to the holder below the optical lens apparatus, fine-tune to fix the focal length and uncover the desired images within seconds.Blood capilliary microcirculation microscope is a non-invasive diagnostic tools, which is gaining large credit among physicians of different specialities in for study of skin blood capilliary network.

microcirculation test machine capillaroscopy machine microscope machine price

Technical parameters

1.magnification over 400 times

2. built-in camera380 000 pixels

3. light source LED

4.brightness of the light source over 600cd/m2

5. Stage X-Y double layer compound mechanical stage

6. Color LCD monitor 8.5inch (4:3) Color LCD monitor 7 inch (16:9)

7.AC input 100-240V50/60Hz DC output DC12V,2A

8. Package aluminum box (Size 40x29x36cm)

9. Gross weight 6.8kg

Testing conditions

1) Check the room temperature and humidity. Room temperature and humidity

should be kept relatively constant. room temperature should be maintained in the 22-24 degree , relative humidity about 70%

2) the patient generally take seats, keep the height of the hand the same with heart

3) Preparation of paraffin oil or cedar oil.Drop 2 drops in the nailfold skin. (Purpose prove light

transmission, and reduce skin scattering)

4)Testing generally be in the morning or afternoon, and review should at the same time every day .

5) the patient should

a.Avoiding intense activity or manual labor within one hour before testing

b. Take a rest about 15-30 minutes before testing

c.Can not take any drug which will affect the cardiovascular vessels before testing

d. Does not smoke , wash hands or eat within an hour before testing

e.Pay attention to the influence of the Female menstrual

 

What is nail microscope microcirculation machine Structure?

1. 8 inch monitor

2. imported chip CCD

3. fine handwheel

4. coarse handwheel

5. platform lateral movement

6. longitudinal movement of the platform

7. finger hold

8. image spot adjustment ( could totate from left and right )

How to use nail microscope microcirculation machine?

Usage of latest medical microcirculation nailfold capillaroscopy machine

1. Fix the screen on the top of the mechanical machines.

2. Plug in the power line and vidao line to the interface of the base.

3. Connect the plug, the plug shows green lights. Press the “Power” button of the screen, wait 3 seconds, the screnn will light.

4. Paint three drops of oil at the position of the intersection of the ring finger nails and skin. Put the oil coated finger in finger hold.

5. Adjuet the coarse hand wheel, when the screen displays images, then adjust fine handwheel. Picture becomes clearer. The bigger one is the coarse adjustable wheel and the small wheel is the fine handwheel. When the machine is about 2-3cm away from the finger, there will be a transparent image on screen.

6. Then, adjuet platform lateral movement handwheel to et a correct position of the first line of the vessel( capillary tube ) and adjuet the fine coarse handwheel to get a clear picture of the vessel. Your fingers will move from left to right on the double loading platform. So try to find the first line of vessels by rotating the platform lateral movement handwheel to change the position of the finger. And finally rotate the fine handwheel ( the position is showed in the structure ) to get a clear picture of the vessels.

7. If there is spot on the screen, rotate the carmera right and left to eliminate it.

nail microscope Microcirculation Microscope Images

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

nail under microscope

 

  • Have any question, Please enter the form below and click the submit button.


    *
    *
    *
    * + * = ?
    Please enter the answer to the sum & Click Submit to verify your registration.

    If the submission is unsuccessful, please refresh your browser page and resubmit.