We are nailfold capillaroscopy,nail fold capillaroscopy,nailfold capillary microscopy factory,Offer OEM.
Nailfold capillaroscopy microscopy

portable nailfold capillary diagnosis microcirculation microscope blood circulation test machine/device/analyzer

TypeBiochemical Analysis System
Brand NameSSCH
Model NumberGY-880
Place of OriginGuangdong, China (Mainland)
Product namenail fold capillary microcirculation microscope
Product featuresMicrocirculation diagnosis
colorblack and white
Warrantyone year
Microscope PackageAluminum box
Microscope Magnification ≥400 times
Built-in camera pixels380000 pixels
microcirculation LCD monitor16*12cm
Input&OutputAC input 100~240V 50/60Hz DC output DC12V,2A
Certificate of microcirculationCE

 How to contact us?

Send your inquiry details in the below, click ‘Send’ now!

We will reply you within 24 hours.

 

Definition:

The micro circulation is by blood, the lymph and tissue fluid flowing which directly participates in the organization, the cell matter, the energy, the information transmission . May directly observe the blood flows in the thin artery, the blood capillary, and the thin vein  through the micro circulation microscope , but if it does not do the special handling is that cannot see clearly the lymph and tissue fluid mobile, therefore, on clinical usually thought the micro circulation  refers to the blood micro circulation in the blood capillary .

 

 

Distributed pattern for  finger nail fold blood capillary 

 

 

 

 

 

 

 

Distributed pattern for  finger nail fold blood capillary

 

The observation for nail fold micro circulation is mainly from three aspects ,including the shape, the fluid state and the blood vessel ansa perimeter  

 

 

 

 

     (Clear)                                                   (Is not clear)                                          (Fuzzy)

 

 

Normal state: Nail fold blood capillary arrangement neat, distribution even, the blood vessel ansa is clearly discernible.

 

Abnormal state: Arrangement disorder, blood vessel ansa fuzzy, is possible to because of the oxygen deficit, the blood stream to be impeded, the Asian health and so on causes.

 

 

Shape of blood vessel ansa :

 

(1) Normal shape likes the hair clip , exceptionally for overlapping and abnormal, the overlapping proportion number should not surpass 30%, the abnormal should not surpass 10%

 

 

(2) abnormal blood vessel:

 

Explained: 1st, the  blood vessel of heart and brain disease, the diabetes, the desmosis and so on, with contract whole body disease or the partial fungus infection and flesh wound and other  organization disease  is easy to appear the blood vessel to be abnormal

 

2nd, when arteriosclerosis,  diabetes with serious abnormal , and the proportion excessive highly.

 

3rd, collagen disease, Reynold sickness, neurosis, the variation of blood vessel increases.

 

 

 

Blood vessel ansa’s periphery

 

After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition:

 

1.Seeps out:  refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery  , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces.

 

2.Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside .

 

Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage  hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on .

 

 

How to use

 

 

 

 

 

 

 

 

 

 

 

 

Testing conditions:

1) Check the room temperature and humidity. Room temperature and humidity

should be kept relatively constant. room temperature should be maintained in the 22-24 degree , relative humidity about 70%

2) the patient generally take seats, keep the height of the hand the same with heart

3) Preparation of paraffin oil or cedar oil.Drop 2 drops in the nailfold skin. (Purpose prove light

transmission, and reduce skin scattering)

4)Testing generally be in the morning or afternoon, and review should at the same time every day .

5) the patient should

a.Avoiding intense activity or manual labor within one hour before testing

b. Take a rest about 15-30 minutes before testing

c.Can not take any drug which will affect the cardiovascular vessels before testing

d. Does not smoke , wash hands or eat within an hour before testing

e.Pay attention to the influence of the Female menstrual

 

 How to contact us?

Send your inquiry details in the below, click ‘Send’ now!

We will reply you within 24 hours.

 

 

  • Have any question, Please enter the form below and click the submit button.


    *
    *
    *
    * + * = ?
    Please enter the answer to the sum & Click Submit to verify your registration.

    If the submission is unsuccessful, please refresh your browser page and resubmit.


    CATEGORY AND TAGS:

    Capillary microcirculation

    Related Items